论文标题
含有$^{169} $ tm的低温检测器获得的太阳轴的共振吸收的新限制
New limits on the resonant absorption of solar axions obtained with a $^{169}$Tm-containing cryogenic detector
论文作者
论文摘要
通过$^{169} $ tm核对太阳轴的谐振吸收进行了搜索。一种新开发的方法,该方法涉及基于TM $ _3 $ _3 $ _5 $ o $ o $ $ _ {12} $ Crystal的低背景低温验仪,与以前的$^{169} $ tm的实验相比,可以显着提高敏感性。在$ 6.6美元的暴露期间以$ 8.18 $ g的晶体执行的尺寸产生了以下限制:$ | g_ {aγ}(g_ {an}^0 + g_ {an}^3) (g_ {an}^0 + g_ {an}^3)\ leq 2.81 \ times 10^{ - 16} $。
A search for resonant absorption of solar axions by $^{169}$Tm nuclei was carried out. A newly developed approach involving low-background cryogenic bolometer based on Tm$_3$Al$_5$O$_{12}$ crystal was used that allowed for significant improvement of sensitivity in comparison with previous $^{169}$Tm based experiments. The measurements performed with $8.18$ g crystal during $6.6$ days exposure yielded the following limits on axion couplings: $|g_{Aγ} (g_{AN}^0 + g_{AN}^3) \leq 1.44 \times 10^{-14}$ GeV$^{-1}$ and $|g_{Ae} (g_{AN}^0 + g_{AN}^3) \leq 2.81 \times 10^{-16}$.